Test Code ZG211 Drug Screen, Urine 9 + Alcohol, Clinical
Additional Codes
Other Mnemonic |
---|
Spectrum: SHO11576 |
Methodology
Kinetic interaction of Micro particles in a Solutions (KIMS)/Enzyme Immunoassay (EIA)
Includes amphetamines, barbiturates, benzodiazepines, cannabinoids, cocaine, ethanol, methadone, opiates, and oxycodone. NOTE: Effective 4.12.17, Spectrum is no longer reporting Phencyclidine as part of this panel.
Performing Laboratory
Spectrum Health Laboratories
Specimen Requirements
Container/Tube: Plastic urine container
Specimen Volume: 10 mL from a random urine collection
Collection Instructions: No preservative
Day(s) Test Set Up
Daily
Specimen Requirements Additional Information
Refrigerate
Reference Values
AMPHETAMINES
Detection limit: 500 ng/mL
BARBITURATES
Detection limit: 200 ng/mL
BENZODIAZEPINES
Detection limit: 300 ng/mL
CANNABINOIDS
Detection limit: 50 ng/mL
COCAINE
Detection limit: 150 ng/mL
ETHANOL
Detection limit: 20 mg/dL
METHADONE
Detection limit: 300 ng/mL
OPIATES
Detection limit: 300 ng/mL
OXYCODONE
Detection limit: 100 ng/mL
PHENCYCLIDINE
NO LONGER REPORTED EFFECTIVE 4.12.17
Note: Positive results should be confirmed by gas chromatography-mass spectrometry (GC-MS) or gas chromatography for ethanol. It is recommended that no action be taken with regard to any positive result unless that drug’s presence is confirmed in the appropriate manner.